Seagate -Uncertified Drive- PowerVault 3220

$
0
0

Help!!

Hi All,

I need some support or guidance on this PowerVault 3220 SAS issue. I have the following firmware on the PowerVault:

MD Storage Manager®                                        
   AMW Version:              11.20.0G06.0001               
   Report Date:              Wed Feb 10 15:55:01 MST 2016  
                                                           
Storage Array                                              
   Storage Array Name:       APEX-DAS1                     
   Current Package Version:  08.20.12.60                   
   Current NVSRAM Version:   N26X0-820890-008              
   Staged Package Version:   None                          
   Staged NVSRAM Version:    None                          
                                                           
RAID Controller Modules                                    
   Location:                 Enclosure 0, Slot 0           
   Current Package Version:  08.20.12.60                   
   Current NVSRAM Version:   N26X0-820890-008              
   Board ID:                 2660                          
   Sub-Model ID:             136                           
                                                           
   Location:                 Enclosure 0, Slot 1           
   Current Package Version:  08.20.12.60                   
   Current NVSRAM Version:   N26X0-820890-008              
   Board ID:                 2660                          
   Sub-Model ID:             136                      

There was failure on slot 3 as you can see below it does not contain current firmware.

Enclosure, Drawer, Slot:     Manufacturer:     Product ID:          Physical Disk Type:            Capacity:        Physical Disk firmware version:     FPGA Version: (SSD only)  
   Enclosure 0, Slot 0          SEAGATE           ST9300653SS          Serial Attached SCSI (SAS)     278.896 GB       YS08                                Not Available             
   Enclosure 0, Slot 1          SEAGATE           ST9300653SS          Serial Attached SCSI (SAS)     278.896 GB       YS08                                Not Available             
   Enclosure 0, Slot 2          SEAGATE           ST9300653SS          Serial Attached SCSI (SAS)     278.896 GB       YS08                                Not Available             
   Enclosure 0, Slot 3          SEAGATE           ST9300653SS          Serial Attached SCSI (SAS)     279.396 GB       0002                                Not Available             
   Enclosure 0, Slot 4          SEAGATE           ST9300653SS          Serial Attached SCSI (SAS)     278.896 GB       YS08                                Not Available             
   Enclosure 0, Slot 5          SEAGATE           ST9300653SS          Serial Attached SCSI (SAS)     278.896 GB       YS08                                Not Available             
   Enclosure 0, Slot 6          SEAGATE           ST9300653SS          Serial Attached SCSI (SAS)     278.896 GB       YS08                                Not Available             
   Enclosure 0, Slot 7          SEAGATE           ST9300653SS          Serial Attached SCSI (SAS)     278.896 GB       YS08                                Not Available            

I have located a older firmware YS0A, however am unable to apply to single drive due to the uncertified status.

Anyone got suggestions? I have seen a thread on here stating to update controller firmware, however it contains the latest. I don't have any free slots to create another array. So, I am kinda stuck on how to get this single drive updated. I do have another Dell system I could possibly update the firmware using Linux (VMWare Host) update...however that is just as difficult for down time. Is there a method around this to update single SAS drive firmware?

I thought Dell updated firmware so that this non-Dell purchased Hard Drive would be resolved. However seems not to be the case.

If any one has suggestions, or further questions. Please let me know.