PowerVault MD3220i Event 1710 wide port has gone to failed state

$
0
0

Hello to all!

We are experiencing problems with  a PowerVault MD3220i.. A cluster that connects to this SAN,  suddenly disconnects, or fail over.

The Dell Modular Disk Storage Manager Client, sends this error:

Summary:

Node ID: XXXX

Event Error Code: 1710

Event Message: RAID Controller Module wide port has gone to failed state

Event Priority: Critical Component

Type: RAID Controller Module Component

Location: Enclosure 0, Slot 0

when we retrive all the logs, we see this:

Date/Time: 8/4/16 8:05:24 PM
Sequence number: 196413
Event type: 5401
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Premium feature disabled
Event specific codes: 0/0/0
Component type: RAID Controller Module Firmware
Component location: None
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 3d ff 02 00 00 00 00 00
01 54 40 00 74 02 a4 57 00 00 00 00 31 80 00 00
00 00 00 00 04 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:05:24 PM
Sequence number: 196412
Event type: 5401
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Premium feature disabled
Event specific codes: 0/0/0
Component type: RAID Controller Module Firmware
Component location: None
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 3c ff 02 00 00 00 00 00
01 54 40 00 74 02 a4 57 00 00 00 00 30 80 00 00
00 00 00 00 04 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:05:17 PM
Sequence number: 196411
Event type: 2024
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Media scan resumed
Event specific codes: 0/0/0
Component type: Virtual Disk
Component location: Virtual Disk CLUSTER02-VM-LUN4
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 3b ff 02 00 00 00 00 00
24 20 4d 00 6d 02 a4 57 02 00 00 10 00 00 00 00
02 00 00 00 04 00 00 00 0d 00 00 00 0d 00 00 00
2a 00 00 00 00 41 00 5a 00 55 00 50 00 43 00 4c
00 55 00 53 00 54 00 45 00 52 00 30 00 32 00 2d
00 56 00 4d 00 2d 00 4c 00 55 00 4e 00 34 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 01 01 14 00 00 00 10 00 13 06
01 00 00 00 00 00 00 00 00 e0 be 24 00 00 00 00

Date/Time: 8/4/16 8:05:17 PM
Sequence number: 196410
Event type: 2024
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Media scan resumed
Event specific codes: 0/0/0
Component type: Virtual Disk
Component location: Virtual Disk CLUSTER02-VM-LUN5
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 3a ff 02 00 00 00 00 00
24 20 4d 00 6d 02 a4 57 03 00 00 10 00 00 00 00
03 00 00 00 04 00 00 00 0d 00 00 00 0d 00 00 00
2a 00 00 00 00 41 00 5a 00 55 00 50 00 43 00 4c
00 55 00 53 00 54 00 45 00 52 00 30 00 32 00 2d
00 56 00 4d 00 2d 00 4c 00 55 00 4e 00 35 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 01 01 14 00 00 00 10 00 13 06
01 00 00 00 00 00 00 00 00 20 82 0d 00 00 00 00

Date/Time: 8/4/16 8:05:17 PM
Sequence number: 196409
Event type: 212C
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Virtual disk write-back caching restored
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 1
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 39 ff 02 00 00 00 00 00
2c 21 48 00 6d 02 a4 57 00 00 00 00 00 00 00 00
ff ff ff ff 04 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 02 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:05:14 PM
Sequence number: 196408
Event type: 2023
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Media scan completed
Event specific codes: 0/0/0
Component type: Virtual Disk
Component location: Virtual Disk CLUSTER02-VM-LUN5
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 38 ff 02 00 00 00 00 00
23 20 4d 00 6a 02 a4 57 03 00 00 10 00 00 00 00
03 00 00 00 04 00 00 00 0d 00 00 00 0d 00 00 00
2a 00 00 00 00 41 00 5a 00 55 00 50 00 43 00 4c
00 55 00 53 00 54 00 45 00 52 00 30 00 32 00 2d
00 56 00 4d 00 2d 00 4c 00 55 00 4e 00 35 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 01 01 14 00 00 00 10 00 18 06
05 00 00 00 09 00 00 00 00 00 00 00 00 00 00 00

Date/Time: 8/4/16 8:05:14 PM
Sequence number: 196407
Event type: 2023
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Media scan completed
Event specific codes: 0/0/0
Component type: Virtual Disk
Component location: Virtual Disk CLUSTER02-VM-LUN4
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 37 ff 02 00 00 00 00 00
23 20 4d 00 6a 02 a4 57 02 00 00 10 00 00 00 00
02 00 00 00 04 00 00 00 0d 00 00 00 0d 00 00 00
2a 00 00 00 00 41 00 5a 00 55 00 50 00 43 00 4c
00 55 00 53 00 54 00 45 00 52 00 30 00 32 00 2d
00 56 00 4d 00 2d 00 4c 00 55 00 4e 00 34 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 01 01 14 00 00 00 10 00 18 06
05 00 00 00 09 00 00 00 00 00 00 00 00 00 00 00

Date/Time: 8/4/16 8:05:13 PM
Sequence number: 196406
Event type: 2101
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Alternate RAID controller module checked in late
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 1
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 36 ff 02 00 00 00 00 00
01 21 48 00 69 02 a4 57 00 00 00 00 00 00 00 00
ff ff ff ff 04 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 02 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:04:56 PM
Sequence number: 196405
Event type: 5401
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Premium feature disabled
Event specific codes: 0/0/0
Component type: RAID Controller Module Firmware
Component location: None
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 35 ff 02 00 00 00 00 00
01 54 40 00 58 02 a4 57 00 00 00 00 31 80 00 00
00 00 00 00 04 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:04:56 PM
Sequence number: 196404
Event type: 5401
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Premium feature disabled
Event specific codes: 0/0/0
Component type: RAID Controller Module Firmware
Component location: None
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 34 ff 02 00 00 00 00 00
01 54 40 00 58 02 a4 57 00 00 00 00 30 80 00 00
00 00 00 00 04 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:04:56 PM
Sequence number: 196403
Event type: 5401
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Premium feature disabled
Event specific codes: 0/0/0
Component type: RAID Controller Module Firmware
Component location: None
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 33 ff 02 00 00 00 00 00
01 54 40 00 58 02 a4 57 00 00 00 00 31 80 00 00
00 00 00 00 04 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:04:56 PM
Sequence number: 196402
Event type: 5401
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Premium feature disabled
Event specific codes: 0/0/0
Component type: RAID Controller Module Firmware
Component location: None
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 32 ff 02 00 00 00 00 00
01 54 40 00 58 02 a4 57 00 00 00 00 30 80 00 00
00 00 00 00 04 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:04:56 PM
Sequence number: 196401
Event type: 5401
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Premium feature disabled
Event specific codes: 0/0/0
Component type: RAID Controller Module Firmware
Component location: None
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 31 ff 02 00 00 00 00 00
01 54 40 00 58 02 a4 57 00 00 00 00 31 80 00 00
00 00 00 00 04 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:04:56 PM
Sequence number: 196400
Event type: 5401
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Premium feature disabled
Event specific codes: 0/0/0
Component type: RAID Controller Module Firmware
Component location: None
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 30 ff 02 00 00 00 00 00
01 54 40 00 58 02 a4 57 00 00 00 00 30 80 00 00
00 00 00 00 04 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:04:56 PM
Sequence number: 196399
Event type: 5401
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Premium feature disabled
Event specific codes: 0/0/0
Component type: RAID Controller Module Firmware
Component location: None
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 2f ff 02 00 00 00 00 00
01 54 40 00 58 02 a4 57 00 00 00 00 05 80 00 00
00 00 00 00 04 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:04:52 PM
Sequence number: 196398
Event type: 282C
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Expansion enclosure path redundancy lost condition resolved
Event specific codes: 0/0/0
Component type: Enclosure
Component location: Enclosure 0
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 2e ff 02 00 00 00 00 00
2c 28 4a 00 54 02 a4 57 00 00 00 00 00 00 00 00
00 00 00 00 04 00 00 00 22 00 00 00 22 00 00 00
0a 00 00 00 00 00 00 00 01 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 36 00 01 01 08 00 00 00 04 00 00 08
00 00 00 00


Date/Time: 8/4/16 8:04:41 PM
Sequence number: 196397
Event type: 281A
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Temperature optimal
Event specific codes: 0/0/0
Component type: Temperature Sensor
Component location: Enclosure 0, RAID Controller Module 0, Slot 1
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 2d ff 02 00 00 00 00 00
1a 28 4a 00 49 02 a4 57 04 00 00 00 00 00 00 00
00 00 00 00 04 00 00 00 22 00 00 00 22 00 00 00
05 00 00 00 00 00 00 00 01 00 00 00 02 00 00 00
08 00 00 00 01 00 00 00 0a 00 00 00 01 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 01 00 01 02 10 00 00 00 04 00 00 08
00 00 00 00 04 00 26 08 01 00 00 00


Date/Time: 8/4/16 8:04:36 PM
Sequence number: 196396
Event type: 1712
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: RAID Controller Module wide port has gone to optimal state
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 0
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 2c ff 02 00 00 00 00 00
12 17 48 00 44 02 a4 57 14 00 00 00 00 01 00 00
00 00 00 00 04 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 01 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 01 02 10 00 00 00 04 00 00 08
00 00 00 00 04 00 26 08 01 00 00 00


Date/Time: 8/4/16 8:04:36 PM
Sequence number: 196395
Event type: 1712
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: RAID Controller Module wide port has gone to optimal state
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 1
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 2b ff 02 00 00 00 00 00
12 17 48 00 44 02 a4 57 14 00 00 00 00 01 01 00
00 00 00 00 04 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 02 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 01 02 10 00 00 00 04 00 00 08
00 00 00 00 04 00 26 08 02 00 00 00


Date/Time: 8/4/16 8:04:26 PM
Sequence number: 196394
Event type: 100D
Event category: Error
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Physical disk command timed out
Event specific codes: 0/0/0
Component type: Physical Disk
Component location: Enclosure 0, Slot 19
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 2a ff 02 00 00 00 00 00
0d 10 11 10 3a 02 a4 57 13 00 01 00 09 01 00 00
01 00 00 00 01 00 00 00 22 00 00 00 22 00 00 00
01 00 00 00 00 00 00 00 14 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 02 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:04:26 PM
Sequence number: 196393
Event type: 100D
Event category: Error
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Physical disk command timed out
Event specific codes: 0/0/0
Component type: Physical Disk
Component location: Enclosure 0, Slot 22
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 29 ff 02 00 00 00 00 00
0d 10 11 10 3a 02 a4 57 16 00 01 00 09 01 00 00
02 00 00 00 01 00 00 00 22 00 00 00 22 00 00 00
01 00 00 00 00 00 00 00 17 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 02 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:04:26 PM
Sequence number: 196392
Event type: 100D
Event category: Error
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Physical disk command timed out
Event specific codes: 0/0/0
Component type: Physical Disk
Component location: Enclosure 0, Slot 21
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 28 ff 02 00 00 00 00 00
0d 10 11 10 3a 02 a4 57 15 00 01 00 09 01 00 00
02 00 00 00 01 00 00 00 22 00 00 00 22 00 00 00
01 00 00 00 00 00 00 00 16 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 02 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:04:26 PM
Sequence number: 196391
Event type: 100D
Event category: Error
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Physical disk command timed out
Event specific codes: 0/0/0
Component type: Physical Disk
Component location: Enclosure 0, Slot 16
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 27 ff 02 00 00 00 00 00
0d 10 11 10 3a 02 a4 57 10 00 01 00 09 01 00 00
01 00 00 00 01 00 00 00 22 00 00 00 22 00 00 00
01 00 00 00 00 00 00 00 11 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 02 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:04:26 PM
Sequence number: 196390
Event type: 100D
Event category: Error
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Physical disk command timed out
Event specific codes: 0/0/0
Component type: Physical Disk
Component location: Enclosure 0, Slot 17
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 26 ff 02 00 00 00 00 00
0d 10 11 10 3a 02 a4 57 11 00 01 00 09 01 00 00
04 00 00 00 01 00 00 00 22 00 00 00 22 00 00 00
01 00 00 00 00 00 00 00 12 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 02 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:04:26 PM
Sequence number: 196389
Event type: 100D
Event category: Error
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Physical disk command timed out
Event specific codes: 0/0/0
Component type: Physical Disk
Component location: Enclosure 0, Slot 12
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 25 ff 02 00 00 00 00 00
0d 10 11 10 3a 02 a4 57 0c 00 01 00 09 01 00 00
03 00 00 00 01 00 00 00 22 00 00 00 22 00 00 00
01 00 00 00 00 00 00 00 0d 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 02 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:04:26 PM
Sequence number: 196388
Event type: 100D
Event category: Error
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Physical disk command timed out
Event specific codes: 0/0/0
Component type: Physical Disk
Component location: Enclosure 0, Slot 18
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 24 ff 02 00 00 00 00 00
0d 10 11 10 3a 02 a4 57 12 00 01 00 09 01 00 00
02 00 00 00 01 00 00 00 22 00 00 00 22 00 00 00
01 00 00 00 00 00 00 00 13 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 02 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:04:26 PM
Sequence number: 196387
Event type: 100D
Event category: Error
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Physical disk command timed out
Event specific codes: 0/0/0
Component type: Physical Disk
Component location: Enclosure 0, Slot 14
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 23 ff 02 00 00 00 00 00
0d 10 11 10 3a 02 a4 57 0e 00 01 00 09 01 00 00
04 00 00 00 01 00 00 00 22 00 00 00 22 00 00 00
01 00 00 00 00 00 00 00 0f 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 02 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:04:26 PM
Sequence number: 196386
Event type: 100D
Event category: Error
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Physical disk command timed out
Event specific codes: 0/0/0
Component type: Physical Disk
Component location: Enclosure 0, Slot 23
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 22 ff 02 00 00 00 00 00
0d 10 11 10 3a 02 a4 57 17 00 01 00 09 01 00 00
06 00 00 00 01 00 00 00 22 00 00 00 22 00 00 00
01 00 00 00 00 00 00 00 18 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 02 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:04:26 PM
Sequence number: 196385
Event type: 100D
Event category: Error
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Physical disk command timed out
Event specific codes: 0/0/0
Component type: Physical Disk
Component location: Enclosure 0, Slot 15
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 21 ff 02 00 00 00 00 00
0d 10 11 10 3a 02 a4 57 0f 00 01 00 09 01 00 00
0e 00 00 00 01 00 00 00 22 00 00 00 22 00 00 00
01 00 00 00 00 00 00 00 10 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 02 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:04:25 PM
Sequence number: 196384
Event type: 100D
Event category: Error
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Physical disk command timed out
Event specific codes: 0/0/0
Component type: Physical Disk
Component location: Enclosure 0, Slot 13
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 20 ff 02 00 00 00 00 00
0d 10 11 10 39 02 a4 57 0d 00 01 00 09 01 00 00
08 00 00 00 01 00 00 00 22 00 00 00 22 00 00 00
01 00 00 00 00 00 00 00 0e 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 02 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:04:15 PM
Sequence number: 196383
Event type: 400B
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Alternate RAID controller module removed or replaced
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 1
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 1f ff 02 00 00 00 00 00
0b 40 48 00 2f 02 a4 57 00 00 00 00 00 00 00 00
00 00 00 00 04 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 02 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:04:15 PM
Sequence number: 196382
Event type: 3101
Event category: Internal
Priority: Debug
Event needs attention: false
Event send alert: false
Event visibility: false
Description: Asynchronous event notification (AEN) posted for recently logged event
Event specific codes: 6/95/2
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 1
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 1e ff 02 00 00 00 00 00
01 31 48 00 2f 02 a4 57 00 00 00 00 00 00 00 00
00 00 00 00 04 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 02 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 01 04 80 00 00 00 20 00 00 01
70 00 06 00 00 00 00 00 00 00 00 9e 00 00 00 00
95 02 00 00 00 00 00 00 01 00 00 00 00 00 00 00
20 00 00 81 00 00 00 00 00 00 00 00 00 08 18 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 20 00 00 81 32 31 4a 30 30 33 44 20
20 20 20 20 20 20 20 20 07 84 47 00 00 00 ff 00
00 00 00 00 00 00 00 00 10 00 00 81 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 ff


Date/Time: 8/4/16 8:05:25 PM
Sequence number: 196381
Event type: 2605
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Start-of-day routine completed
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 0
Logged by: RAID Controller Module in slot 0

Raw data:
4d 45 4c 48 03 00 00 00 1d ff 02 00 00 00 00 00
05 26 48 10 75 02 a4 57 00 00 00 00 00 00 00 00
00 00 00 00 04 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 01 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 00 01 08 00 00 00 04 00 00 00
01 00 00 00


Date/Time: 8/4/16 8:05:23 PM
Sequence number: 196380
Event type: 5401
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Premium feature disabled
Event specific codes: 0/0/0
Component type: RAID Controller Module Firmware
Component location: None
Logged by: RAID Controller Module in slot 0

Raw data:
4d 45 4c 48 03 00 00 00 1c ff 02 00 00 00 00 00
01 54 40 00 73 02 a4 57 00 00 00 00 31 80 00 00
00 00 00 00 04 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00


Date/Time: 8/4/16 8:05:23 PM
Sequence number: 196379
Event type: 5401
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Premium feature disabled
Event specific codes: 0/0/0
Component type: RAID Controller Module Firmware
Component location: None
Logged by: RAID Controller Module in slot 0

Raw data:
4d 45 4c 48 03 00 00 00 1b ff 02 00 00 00 00 00
01 54 40 00 73 02 a4 57 00 00 00 00 30 80 00 00
00 00 00 00 04 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00


Date/Time: 8/4/16 8:05:17 PM
Sequence number: 196378
Event type: 2102
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Cache not synchronized
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 0
Logged by: RAID Controller Module in slot 0

Raw data:
4d 45 4c 48 03 00 00 00 1a ff 02 00 00 00 00 00
02 21 48 00 6d 02 a4 57 00 00 00 00 00 00 00 00
ff ff ff ff 04 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 01 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 00 00 00 00 00 00


Date/Time: 8/4/16 8:05:07 PM
Sequence number: 196377
Event type: 1814
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: iSCSI carrier detected
Event specific codes: 0/0/0
Component type: Channel
Component location: Host-side: RAID controller module in slot 0, port 4
Logged by: RAID Controller Module in slot 0

Raw data:
4d 45 4c 48 03 00 00 00 19 ff 02 00 00 00 00 00
14 18 49 02 63 02 a4 57 00 00 00 00 00 00 00 00
04 10 00 00 04 00 00 00 06 00 00 00 06 00 00 00
00 00 00 00 04 00 00 00 01 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 00 00 00 00 00 00


Date/Time: 8/4/16 8:05:07 PM
Sequence number: 196376
Event type: 1814
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: iSCSI carrier detected
Event specific codes: 0/0/0
Component type: Channel
Component location: Host-side: RAID controller module in slot 0, port 3
Logged by: RAID Controller Module in slot 0

Raw data:
4d 45 4c 48 03 00 00 00 18 ff 02 00 00 00 00 00
14 18 49 02 63 02 a4 57 00 00 00 00 00 00 00 00
03 10 00 00 04 00 00 00 06 00 00 00 06 00 00 00
00 00 00 00 03 00 00 00 01 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 00 00 00 00 00 00


Date/Time: 8/4/16 8:05:07 PM
Sequence number: 196375
Event type: 1814
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: iSCSI carrier detected
Event specific codes: 0/0/0
Component type: Channel
Component location: Host-side: RAID controller module in slot 0, port 2
Logged by: RAID Controller Module in slot 0

Raw data:
4d 45 4c 48 03 00 00 00 17 ff 02 00 00 00 00 00
14 18 49 02 63 02 a4 57 00 00 00 00 00 00 00 00
02 10 00 00 04 00 00 00 06 00 00 00 06 00 00 00
00 00 00 00 02 00 00 00 01 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 00 00 00 00 00 00


Date/Time: 8/4/16 8:05:07 PM
Sequence number: 196374
Event type: 1814
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: iSCSI carrier detected
Event specific codes: 0/0/0
Component type: Channel
Component location: Host-side: RAID controller module in slot 0, port 1
Logged by: RAID Controller Module in slot 0

Raw data:
4d 45 4c 48 03 00 00 00 16 ff 02 00 00 00 00 00
14 18 49 02 63 02 a4 57 00 00 00 00 00 00 00 00
01 10 00 00 04 00 00 00 06 00 00 00 06 00 00 00
00 00 00 00 01 00 00 00 01 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 00 00 00 00 00 00


Date/Time: 8/4/16 8:04:57 PM
Sequence number: 196373
Event type: 2112
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Battery fully charged
Event specific codes: 0/0/0
Component type: Battery Pack
Component location: Enclosure 0, RAID Controller Module 0, Slot 0
Logged by: RAID Controller Module in slot 0

Raw data:
4d 45 4c 48 03 00 00 00 15 ff 02 00 00 00 00 00
12 21 49 00 59 02 a4 57 09 00 00 00 00 00 00 00
00 00 00 00 04 00 00 00 22 00 00 00 22 00 00 00
09 00 00 00 00 00 00 00 01 00 00 00 02 00 00 00
08 00 00 00 01 00 00 00 0a 00 00 00 01 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 01 00 00 02 2c 00 00 00 20 00 00 0c
00 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
bb 1a 00 00 20 00 00 00 ba 18 00 00 ba 18 00 00
04 00 00 8c 00 00 00 00


Date/Time: 8/4/16 8:04:56 PM
Sequence number: 196372
Event type: 5401
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Premium feature disabled
Event specific codes: 0/0/0
Component type: RAID Controller Module Firmware
Component location: None
Logged by: RAID Controller Module in slot 0

Raw data:
4d 45 4c 48 03 00 00 00 14 ff 02 00 00 00 00 00
01 54 40 00 58 02 a4 57 00 00 00 00 31 80 00 00
00 00 00 00 04 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00


Date/Time: 8/4/16 8:04:56 PM
Sequence number: 196371
Event type: 5401
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Premium feature disabled
Event specific codes: 0/0/0
Component type: RAID Controller Module Firmware
Component location: None
Logged by: RAID Controller Module in slot 0

Raw data:
4d 45 4c 48 03 00 00 00 13 ff 02 00 00 00 00 00
01 54 40 00 58 02 a4 57 00 00 00 00 30 80 00 00
00 00 00 00 04 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00


Date/Time: 8/4/16 8:04:56 PM
Sequence number: 196370
Event type: 5401
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Premium feature disabled
Event specific codes: 0/0/0
Component type: RAID Controller Module Firmware
Component location: None
Logged by: RAID Controller Module in slot 0

Raw data:
4d 45 4c 48 03 00 00 00 12 ff 02 00 00 00 00 00
01 54 40 00 58 02 a4 57 00 00 00 00 31 80 00 00
00 00 00 00 04 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00


Date/Time: 8/4/16 8:04:56 PM
Sequence number: 196369
Event type: 5401
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Premium feature disabled
Event specific codes: 0/0/0
Component type: RAID Controller Module Firmware
Component location: None
Logged by: RAID Controller Module in slot 0

Raw data:
4d 45 4c 48 03 00 00 00 11 ff 02 00 00 00 00 00
01 54 40 00 58 02 a4 57 00 00 00 00 30 80 00 00
00 00 00 00 04 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00


Date/Time: 8/4/16 8:04:56 PM
Sequence number: 196368
Event type: 5401
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Premium feature disabled
Event specific codes: 0/0/0
Component type: RAID Controller Module Firmware
Component location: None
Logged by: RAID Controller Module in slot 0

Raw data:
4d 45 4c 48 03 00 00 00 10 ff 02 00 00 00 00 00
01 54 40 00 58 02 a4 57 00 00 00 00 31 80 00 00
00 00 00 00 04 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00


Date/Time: 8/4/16 8:04:56 PM
Sequence number: 196367
Event type: 5401
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Premium feature disabled
Event specific codes: 0/0/0
Component type: RAID Controller Module Firmware
Component location: None
Logged by: RAID Controller Module in slot 0

Raw data:
4d 45 4c 48 03 00 00 00 0f ff 02 00 00 00 00 00
01 54 40 00 58 02 a4 57 00 00 00 00 30 80 00 00
00 00 00 00 04 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00


Date/Time: 8/4/16 8:04:56 PM
Sequence number: 196366
Event type: 5401
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Premium feature disabled
Event specific codes: 0/0/0
Component type: RAID Controller Module Firmware
Component location: None
Logged by: RAID Controller Module in slot 0

Raw data:
4d 45 4c 48 03 00 00 00 0e ff 02 00 00 00 00 00
01 54 40 00 58 02 a4 57 00 00 00 00 05 80 00 00
00 00 00 00 04 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00


Date/Time: 8/4/16 8:04:52 PM
Sequence number: 196365
Event type: 4010
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: RAID controller module reset itself
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 0
Logged by: RAID Controller Module in slot 0

Raw data:
4d 45 4c 48 03 00 00 00 0d ff 02 00 00 00 00 00
10 40 48 00 54 02 a4 57 00 00 00 00 00 00 00 00
00 00 00 00 04 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 01 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 00 01 14 00 00 00 10 00 10 07
0b 00 07 04 00 00 00 00 54 02 a4 57 00 00 00 00

Date/Time: 8/4/16 8:04:43 PM
Sequence number: 196364
Event type: 1712
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: RAID Controller Module wide port has gone to optimal state
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 1
Logged by: RAID Controller Module in slot 0

Raw data:
4d 45 4c 48 03 00 00 00 0c ff 02 00 00 00 00 00
12 17 48 00 4b 02 a4 57 14 00 00 00 00 01 01 00
00 00 00 00 04 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 02 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 00 02 10 00 00 00 04 00 00 08
00 00 00 00 04 00 26 08 02 00 00 00


Date/Time: 8/4/16 8:04:42 PM
Sequence number: 196363
Event type: 1712
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: RAID Controller Module wide port has gone to optimal state
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 0
Logged by: RAID Controller Module in slot 0

Raw data:
4d 45 4c 48 03 00 00 00 0b ff 02 00 00 00 00 00
12 17 48 00 4a 02 a4 57 14 00 00 00 00 01 00 00
00 00 00 00 04 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 01 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 00 02 10 00 00 00 04 00 00 08
00 00 00 00 04 00 26 08 01 00 00 00


Date/Time: 8/4/16 8:04:41 PM
Sequence number: 196362
Event type: 1712
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: RAID Controller Module wide port has gone to optimal state
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 0
Logged by: RAID Controller Module in slot 0

Raw data:
4d 45 4c 48 03 00 00 00 0a ff 02 00 00 00 00 00
12 17 48 00 49 02 a4 57 14 00 00 00 00 00 01 00
00 00 00 00 04 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 01 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 00 02 10 00 00 00 04 00 00 08
00 00 00 00 04 00 26 08 01 00 00 00


Date/Time: 8/4/16 8:04:41 PM
Sequence number: 196361
Event type: 1712
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: RAID Controller Module wide port has gone to optimal state
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 0
Logged by: RAID Controller Module in slot 0

Raw data:
4d 45 4c 48 03 00 00 00 09 ff 02 00 00 00 00 00
12 17 48 00 49 02 a4 57 14 00 00 00 00 00 00 00
00 00 00 00 04 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 01 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 00 02 10 00 00 00 04 00 00 08
00 00 00 00 04 00 26 08 01 00 00 00


Date/Time: 8/4/16 8:04:11 PM
Sequence number: 196360
Event type: 2606
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Start-of-day routine begun
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 0
Logged by: RAID Controller Module in slot 0

Raw data:
4d 45 4c 48 03 00 00 00 08 ff 02 00 00 00 00 00
06 26 48 10 2b 02 a4 57 00 00 00 00 00 00 00 00
00 00 00 00 04 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 01 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 00 01 08 00 00 00 04 00 00 00
01 00 00 00


Date/Time: 8/4/16 8:04:11 PM
Sequence number: 196359
Event type: 102
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: End of delayed events
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: None
Logged by: RAID Controller Module in slot 0

Raw data:
4d 45 4c 48 03 00 00 00 07 ff 02 00 00 00 00 00
02 01 48 00 2b 02 a4 57 00 00 00 00 00 00 00 00
00 00 00 00 04 00 00 00 08 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00


Date/Time: 8/4/16 8:03:03 PM
Sequence number: 196358
Event type: 2606
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Start-of-day routine begun
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 0
Logged by: RAID Controller Module in slot 0

Raw data:
4d 45 4c 48 03 00 00 00 06 ff 02 00 00 00 00 00
06 26 48 10 e7 01 a4 57 00 00 00 00 00 00 00 00
00 00 00 00 04 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 01 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 00 00 00 00 00 00


Date/Time: 8/4/16 8:01:42 PM
Sequence number: 196357
Event type: 1400
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Password reset
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 0
Logged by: RAID Controller Module in slot 0

Raw data:
4d 45 4c 48 03 00 00 00 05 ff 02 00 00 00 00 00
00 14 48 10 96 01 a4 57 00 00 00 00 00 00 00 00
00 00 00 00 04 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 01 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 00 00 00 00 00 00


Date/Time: 8/4/16 8:04:11 PM
Sequence number: 196356
Event type: 101
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Start of delayed events
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: None
Logged by: RAID Controller Module in slot 0

Raw data:
4d 45 4c 48 03 00 00 00 04 ff 02 00 00 00 00 00
01 01 48 00 2b 02 a4 57 00 00 00 00 00 00 00 00
00 00 00 00 04 00 00 00 08 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00


Date/Time: 8/4/16 8:04:06 PM
Sequence number: 196355
Event type: 282B
Event category: Internal
Priority: Warning
Event needs attention: true
Event send alert: true
Event visibility: true
Description: Expansion enclosure path redundancy lost
Event specific codes: 0/0/0
Component type: Enclosure
Component location: Enclosure 0
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 03 ff 02 00 00 00 00 00
2b 28 4a 01 26 02 a4 57 00 00 00 00 00 00 00 00
00 00 00 00 04 00 00 00 22 00 00 00 22 00 00 00
0a 00 00 00 00 00 00 00 01 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 36 00 01 01 08 00 00 00 04 00 00 08
00 00 00 00


Date/Time: 8/4/16 8:04:06 PM
Sequence number: 196354
Event type: 3101
Event category: Internal
Priority: Debug
Event needs attention: false
Event send alert: false
Event visibility: false
Description: Asynchronous event notification (AEN) posted for recently logged event
Event specific codes: 6/e0/20
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 1
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 02 ff 02 00 00 00 00 00
01 31 48 00 26 02 a4 57 00 00 00 00 00 00 00 00
00 00 00 00 04 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 02 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 01 04 80 00 00 00 20 00 00 01
70 00 06 00 00 00 00 00 00 00 00 9e 00 00 00 00
e0 20 09 00 00 00 00 00 01 00 00 00 00 00 00 01
20 00 00 81 00 00 00 00 00 00 00 00 00 08 4a 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 20 00 00 81 32 31 4a 30 30 33 44 20
20 20 20 20 20 20 20 20 07 84 47 00 00 00 ff 06
0f 00 00 00 00 00 00 00 10 00 00 81 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 ff


Date/Time: 8/4/16 8:03:42 PM
Sequence number: 196353
Event type: 2024
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Media scan resumed
Event specific codes: 0/0/0
Component type: Virtual Disk
Component location: Virtual Disk CLUSTER02-VM-LUN4
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 01 ff 02 00 00 00 00 00
24 20 4d 00 0e 02 a4 57 02 00 00 10 00 00 00 00
02 00 00 00 04 00 00 00 0d 00 00 00 0d 00 00 00
2a 00 00 00 00 41 00 5a 00 55 00 50 00 43 00 4c
00 55 00 53 00 54 00 45 00 52 00 30 00 32 00 2d
00 56 00 4d 00 2d 00 4c 00 55 00 4e 00 34 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 01 01 14 00 00 00 10 00 13 06
01 00 00 00 00 00 00 00 00 a0 ae 24 00 00 00 00

Date/Time: 8/4/16 8:03:42 PM
Sequence number: 196352
Event type: 2024
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Media scan resumed
Event specific codes: 0/0/0
Component type: Virtual Disk
Component location: Virtual Disk CLUSTER02-VM-LUN5
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 00 ff 02 00 00 00 00 00
24 20 4d 00 0e 02 a4 57 03 00 00 10 00 00 00 00
03 00 00 00 04 00 00 00 0d 00 00 00 0d 00 00 00
2a 00 00 00 00 41 00 5a 00 55 00 50 00 43 00 4c
00 55 00 53 00 54 00 45 00 52 00 30 00 32 00 2d
00 56 00 4d 00 2d 00 4c 00 55 00 4e 00 35 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 01 01 14 00 00 00 10 00 13 06
01 00 00 00 00 00 00 00 00 e0 7b 0d 00 00 00 00

Date/Time: 8/4/16 8:03:42 PM
Sequence number: 196351
Event type: 400D
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Alternate RAID controller module placed online
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 0
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 ff fe 02 00 00 00 00 00
0d 40 48 80 0e 02 a4 57 00 00 00 00 00 00 00 00
00 00 00 00 04 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 01 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:03:39 PM
Sequence number: 196350
Event type: 2023
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Media scan completed
Event specific codes: 0/0/0
Component type: Virtual Disk
Component location: Virtual Disk CLUSTER02-VM-LUN5
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 fe fe 02 00 00 00 00 00
23 20 4d 00 0b 02 a4 57 03 00 00 10 00 00 00 00
03 00 00 00 04 00 00 00 0d 00 00 00 0d 00 00 00
2a 00 00 00 00 41 00 5a 00 55 00 50 00 43 00 4c
00 55 00 53 00 54 00 45 00 52 00 30 00 32 00 2d
00 56 00 4d 00 2d 00 4c 00 55 00 4e 00 35 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 01 01 14 00 00 00 10 00 18 06
05 00 00 00 09 00 00 00 00 00 00 00 00 00 00 00

Date/Time: 8/4/16 8:03:39 PM
Sequence number: 196349
Event type: 2023
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Media scan completed
Event specific codes: 0/0/0
Component type: Virtual Disk
Component location: Virtual Disk CLUSTER02-VM-LUN4
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 fd fe 02 00 00 00 00 00
23 20 4d 00 0b 02 a4 57 02 00 00 10 00 00 00 00
02 00 00 00 04 00 00 00 0d 00 00 00 0d 00 00 00
2a 00 00 00 00 41 00 5a 00 55 00 50 00 43 00 4c
00 55 00 53 00 54 00 45 00 52 00 30 00 32 00 2d
00 56 00 4d 00 2d 00 4c 00 55 00 4e 00 34 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 01 01 14 00 00 00 10 00 18 06
05 00 00 00 09 00 00 00 00 00 00 00 00 00 00 00

Date/Time: 8/4/16 8:03:35 PM
Sequence number: 196348
Event type: 104
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: true
Event visibility: true
Description: Needs attention condition resolved
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 1
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 fc fe 02 00 00 00 00 00
04 01 40 00 07 02 a4 57 00 00 00 00 00 80 00 00
00 00 00 00 04 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 02 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 01 01 10 00 00 00 0c 00 00 00
0b 28 00 00 00 00 00 00 79 00 00 00


Date/Time: 8/4/16 8:03:30 PM
Sequence number: 196347
Event type: 300D
Event category: Command
Priority: Debug
Event needs attention: false
Event send alert: false
Event visibility: false
Description: SCSI MODE SELECT page 2Ch received
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 1
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 fb fe 02 00 00 00 00 00
0d 30 38 00 02 02 a4 57 00 00 00 00 08 00 00 00
03 00 00 00 03 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 02 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 01 04 7c 00 00 00 20 00 1a 06
32 31 4a 30 30 33 44 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
20 00 1a 86 00 02 00 02 05 02 81 81 81 81 81 81
81 81 81 81 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 20 00 1a 86 00 00 00 00 00 03 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 0a 00 1a 86 00 00 00 00
00 00 00 00 00 00 00 00


Date/Time: 8/4/16 8:03:29 PM
Sequence number: 196346
Event type: 2024
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Media scan resumed
Event specific codes: 0/0/0
Component type: Virtual Disk
Component location: Virtual Disk CLUSTER02-VM-LUN4
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 fa fe 02 00 00 00 00 00
24 20 4d 00 01 02 a4 57 02 00 00 10 00 00 00 00
02 00 00 00 04 00 00 00 0d 00 00 00 0d 00 00 00
2a 00 00 00 00 41 00 5a 00 55 00 50 00 43 00 4c
00 55 00 53 00 54 00 45 00 52 00 30 00 32 00 2d
00 56 00 4d 00 2d 00 4c 00 55 00 4e 00 34 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 01 01 14 00 00 00 10 00 13 06
01 00 00 00 00 00 00 00 00 c0 ac 24 00 00 00 00

Date/Time: 8/4/16 8:03:29 PM
Sequence number: 196345
Event type: 2024
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Media scan resumed
Event specific codes: 0/0/0
Component type: Virtual Disk
Component location: Virtual Disk CLUSTER02-VM-LUN5
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 f9 fe 02 00 00 00 00 00
24 20 4d 00 01 02 a4 57 03 00 00 10 00 00 00 00
03 00 00 00 04 00 00 00 0d 00 00 00 0d 00 00 00
2a 00 00 00 00 41 00 5a 00 55 00 50 00 43 00 4c
00 55 00 53 00 54 00 45 00 52 00 30 00 32 00 2d
00 56 00 4d 00 2d 00 4c 00 55 00 4e 00 35 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 01 01 14 00 00 00 10 00 13 06
01 00 00 00 00 00 00 00 00 a0 7a 0d 00 00 00 00

Date/Time: 8/4/16 8:03:28 PM
Sequence number: 196344
Event type: 300D
Event category: Command
Priority: Debug
Event needs attention: false
Event send alert: false
Event visibility: false
Description: SCSI MODE SELECT page 2Ch received
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 1
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 f8 fe 02 00 00 00 00 00
0d 30 38 00 00 02 a4 57 00 00 00 00 04 00 00 00
09 00 00 00 03 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 02 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 01 04 7c 00 00 00 20 00 1a 06
32 31 4a 30 30 33 44 00 00 00 00 00 00 00 00 00
32 31 4a 30 30 33 4a 00 00 00 00 00 00 00 00 00
20 00 1a 86 00 02 00 02 05 02 81 81 81 81 02 81
81 81 02 81 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 20 00 1a 86 00 00 00 00 00 03 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 0a 00 1a 86 00 00 00 00
00 00 00 00 00 00 00 00


Date/Time: 8/4/16 8:03:28 PM
Sequence number: 196343
Event type: 2013
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Cache recovered unwritten data/parity
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 1
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 f7 fe 02 00 00 00 00 00
13 20 48 00 00 02 a4 57 00 00 00 00 00 00 00 00
09 00 00 00 04 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 02 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 35 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:03:28 PM
Sequence number: 196342
Event type: 2013
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Cache recovered unwritten data/parity
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 1
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 f6 fe 02 00 00 00 00 00
13 20 48 00 00 02 a4 57 00 00 00 00 00 00 00 00
03 00 00 00 04 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 02 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 e0 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:03:28 PM
Sequence number: 196341
Event type: 2013
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Cache recovered unwritten data/parity
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 1
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 f5 fe 02 00 00 00 00 00
13 20 48 00 00 02 a4 57 00 00 00 00 00 00 00 00
02 00 00 00 04 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 02 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 c3 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:03:20 PM
Sequence number: 196340
Event type: 400F
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: RAID controller module reset its alternate
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 0
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 f4 fe 02 00 00 00 00 00
0f 40 48 80 f8 01 a4 57 00 00 00 00 00 00 00 00
00 00 00 00 04 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 01 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 01 01 14 00 00 00 10 00 10 07
05 00 20 04 00 00 00 00 f8 01 a4 57 00 00 00 00

Date/Time: 8/4/16 8:03:20 PM
Sequence number: 196339
Event type: 400C
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Alternate RAID controller module placed offline
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 0
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 f3 fe 02 00 00 00 00 00
0c 40 48 80 f8 01 a4 57 00 00 00 00 00 00 00 00
00 00 00 00 04 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 01 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 01 01 0c 00 00 00 08 00 10 07
05 00 20 04 00 00 00 00


Date/Time: 8/4/16 8:03:17 PM
Sequence number: 196338
Event type: 100D
Event category: Error
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Physical disk command timed out
Event specific codes: 0/0/0
Component type: Physical Disk
Component location: Enclosure 0, Slot 21
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 f2 fe 02 00 00 00 00 00
0d 10 11 10 f5 01 a4 57 15 00 01 00 09 01 00 00
03 00 00 00 01 00 00 00 22 00 00 00 22 00 00 00
01 00 00 00 00 00 00 00 16 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 02 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:03:17 PM
Sequence number: 196337
Event type: 100D
Event category: Error
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Physical disk command timed out
Event specific codes: 0/0/0
Component type: Physical Disk
Component location: Enclosure 0, Slot 22
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 f1 fe 02 00 00 00 00 00
0d 10 11 10 f5 01 a4 57 16 00 01 00 09 01 00 00
06 00 00 00 01 00 00 00 22 00 00 00 22 00 00 00
01 00 00 00 00 00 00 00 17 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 02 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:03:17 PM
Sequence number: 196336
Event type: 100D
Event category: Error
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Physical disk command timed out
Event specific codes: 0/0/0
Component type: Physical Disk
Component location: Enclosure 0, Slot 19
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 f0 fe 02 00 00 00 00 00
0d 10 11 10 f5 01 a4 57 13 00 01 00 09 01 00 00
03 00 00 00 01 00 00 00 22 00 00 00 22 00 00 00
01 00 00 00 00 00 00 00 14 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 02 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:03:17 PM
Sequence number: 196335
Event type: 100D
Event category: Error
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Physical disk command timed out
Event specific codes: 0/0/0
Component type: Physical Disk
Component location: Enclosure 0, Slot 18
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 ef fe 02 00 00 00 00 00
0d 10 11 10 f5 01 a4 57 12 00 01 00 09 01 00 00
06 00 00 00 01 00 00 00 22 00 00 00 22 00 00 00
01 00 00 00 00 00 00 00 13 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 02 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:03:17 PM
Sequence number: 196334
Event type: 100D
Event category: Error
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Physical disk command timed out
Event specific codes: 0/0/0
Component type: Physical Disk
Component location: Enclosure 0, Slot 14
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 ee fe 02 00 00 00 00 00
0d 10 11 10 f5 01 a4 57 0e 00 01 00 09 01 00 00
05 00 00 00 01 00 00 00 22 00 00 00 22 00 00 00
01 00 00 00 00 00 00 00 0f 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 02 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:03:17 PM
Sequence number: 196333
Event type: 100D
Event category: Error
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Physical disk command timed out
Event specific codes: 0/0/0
Component type: Physical Disk
Component location: Enclosure 0, Slot 17
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 ed fe 02 00 00 00 00 00
0d 10 11 10 f5 01 a4 57 11 00 01 00 09 01 00 00
08 00 00 00 01 00 00 00 22 00 00 00 22 00 00 00
01 00 00 00 00 00 00 00 12 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 02 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:03:17 PM
Sequence number: 196332
Event type: 100D
Event category: Error
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Physical disk command timed out
Event specific codes: 0/0/0
Component type: Physical Disk
Component location: Enclosure 0, Slot 13
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 ec fe 02 00 00 00 00 00
0d 10 11 10 f5 01 a4 57 0d 00 01 00 09 01 00 00
07 00 00 00 01 00 00 00 22 00 00 00 22 00 00 00
01 00 00 00 00 00 00 00 0e 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 02 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:03:17 PM
Sequence number: 196331
Event type: 100D
Event category: Error
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Physical disk command timed out
Event specific codes: 0/0/0
Component type: Physical Disk
Component location: Enclosure 0, Slot 12
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 eb fe 02 00 00 00 00 00
0d 10 11 10 f5 01 a4 57 0c 00 01 00 09 01 00 00
0a 00 00 00 01 00 00 00 22 00 00 00 22 00 00 00
01 00 00 00 00 00 00 00 0d 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 02 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:03:17 PM
Sequence number: 196330
Event type: 100D
Event category: Error
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Physical disk command timed out
Event specific codes: 0/0/0
Component type: Physical Disk
Component location: Enclosure 0, Slot 23
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 ea fe 02 00 00 00 00 00
0d 10 11 10 f5 01 a4 57 17 00 01 00 09 01 00 00
06 00 00 00 01 00 00 00 22 00 00 00 22 00 00 00
01 00 00 00 00 00 00 00 18 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 02 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:03:17 PM
Sequence number: 196329
Event type: 100D
Event category: Error
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Physical disk command timed out
Event specific codes: 0/0/0
Component type: Physical Disk
Component location: Enclosure 0, Slot 20
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 e9 fe 02 00 00 00 00 00
0d 10 11 10 f5 01 a4 57 14 00 01 00 09 01 00 00
07 00 00 00 01 00 00 00 22 00 00 00 22 00 00 00
01 00 00 00 00 00 00 00 15 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 02 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:03:17 PM
Sequence number: 196328
Event type: 100D
Event category: Error
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Physical disk command timed out
Event specific codes: 0/0/0
Component type: Physical Disk
Component location: Enclosure 0, Slot 15
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 e8 fe 02 00 00 00 00 00
0d 10 11 10 f5 01 a4 57 0f 00 01 00 09 01 00 00
0b 00 00 00 01 00 00 00 22 00 00 00 22 00 00 00
01 00 00 00 00 00 00 00 10 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 02 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:03:17 PM
Sequence number: 196327
Event type: 100D
Event category: Error
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Physical disk command timed out
Event specific codes: 0/0/0
Component type: Physical Disk
Component location: Enclosure 0, Slot 16
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 e7 fe 02 00 00 00 00 00
0d 10 11 10 f5 01 a4 57 10 00 01 00 09 01 00 00
0c 00 00 00 01 00 00 00 22 00 00 00 22 00 00 00
01 00 00 00 00 00 00 00 11 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 02 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:03:06 PM
Sequence number: 196326
Event type: 400B
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Alternate RAID controller module removed or replaced
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 1
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 e6 fe 02 00 00 00 00 00
0b 40 48 00 ea 01 a4 57 00 00 00 00 00 00 00 00
00 00 00 00 04 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 02 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:03:06 PM
Sequence number: 196325
Event type: 3101
Event category: Internal
Priority: Debug
Event needs attention: false
Event send alert: false
Event visibility: false
Description: Asynchronous event notification (AEN) posted for recently logged event
Event specific codes: 6/95/2
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 1
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 e5 fe 02 00 00 00 00 00
01 31 48 00 ea 01 a4 57 00 00 00 00 00 00 00 00
00 00 00 00 04 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 02 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 01 04 80 00 00 00 20 00 00 01
70 00 06 00 00 00 00 00 00 00 00 9e 00 00 00 00
95 02 00 00 00 00 00 00 01 00 00 00 00 00 00 00
20 00 00 81 00 00 00 00 00 00 00 00 00 08 18 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 20 00 00 81 32 31 4a 30 30 33 44 20
20 20 20 20 20 20 20 20 07 84 47 00 00 00 ff 00
00 00 00 00 00 00 00 00 10 00 00 81 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 ff


Date/Time: 8/4/16 8:02:58 PM
Sequence number: 196324
Event type: 1710
Event category: Error
Priority: Critical
Event needs attention: true
Event send alert: true
Event visibility: true
Description: RAID Controller Module wide port has gone to failed state
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 0
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 e4 fe 02 00 00 00 00 00
10 17 18 01 e2 01 a4 57 14 00 00 00 00 01 00 00
00 00 00 00 01 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 01 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 01 02 10 00 00 00 04 00 00 08
00 00 00 00 04 00 26 08 01 00 00 00


Date/Time: 8/4/16 8:02:57 PM
Sequence number: 196323
Event type: 1710
Event category: Error
Priority: Critical
Event needs attention: true
Event send alert: true
Event visibility: true
Description: RAID Controller Module wide port has gone to failed state
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 1
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 e3 fe 02 00 00 00 00 00
10 17 18 01 e1 01 a4 57 14 00 00 00 00 01 01 00
00 00 00 00 01 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 02 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 01 02 10 00 00 00 04 00 00 08
00 00 00 00 04 00 26 08 02 00 00 00


Date/Time: 8/4/16 8:02:34 PM
Sequence number: 196322
Event type: 2102
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Cache not synchronized
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 1
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 e2 fe 02 00 00 00 00 00
02 21 48 00 ca 01 a4 57 00 00 00 00 00 00 00 00
ff ff ff ff 04 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 02 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:02:33 PM
Sequence number: 196321
Event type: 400D
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Alternate RAID controller module placed online
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 0
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 e1 fe 02 00 00 00 00 00
0d 40 48 80 c9 01 a4 57 00 00 00 00 00 00 00 00
00 00 00 00 04 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 01 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 01 00 00 00 00 00


Date/Time: 8/4/16 8:02:28 PM
Sequence number: 196320
Event type: 1012
Event category: Error
Priority: Debug
Event needs attention: false
Event send alert: false
Event visibility: false
Description: Destination driver error
Event specific codes: 1ff00/2/0
Component type: Physical Disk
Component location: Enclosure Unknown, Slot UNKNOWN
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 e0 fe 02 00 00 00 00 00
12 10 11 10 c4 01 a4 57 11 00 f0 00 00 00 00 00
0b 00 00 00 01 00 00 00 22 00 00 00 22 00 00 00
01 00 00 00 64 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 01 00 01 04 7c 00 00 00 20 00 12 01
00 ff 01 00 02 00 00 00 00 00 00 00 ca 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 19 00 86 76
20 00 12 81 00 01 00 00 ff 03 02 04 ee ee ee ee
00 62 01 04 02 b7 e5 02 01 29 00 01 ff 02 02 00
01 b0 00 01 20 00 12 81 02 b4 00 00 02 49 00 01
ff 02 02 00 00 00 00 00 ff 00 00 00 00 00 00 00
ff 00 00 00 00 00 00 00 0c 00 12 81 ff 00 00 00
00 00 00 00 ff 00 00 00


Date/Time: 8/4/16 8:02:28 PM
Sequence number: 196319
Event type: 210A
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Cache not enabled
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 1
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 df fe 02 00 00 00 00 00
0a 21 48 00 c4 01 a4 57 00 00 00 00 00 80 00 00
00 00 00 00 04 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 02 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 01 04 80 00 00 00 20 00 00 00
4d 69 72 72 6f 72 20 43 68 61 6e 6e 65 6c 20 46
61 69 6c 75 72 65 2c 43 6f 6e 74 72 6f 6c 6c 65
20 00 00 00 72 20 6e 6f 74 20 4f 70 74 69 6d 61
6c 2d 32 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 20 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 10 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00


Date/Time: 8/4/16 8:02:25 PM
Sequence number: 196318
Event type: 400F
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: RAID controller module reset its alternate
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 0
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 de fe 02 00 00 00 00 00
0f 40 48 80 c1 01 a4 57 00 00 00 00 00 00 00 00
00 00 00 00 04 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 01 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 01 01 14 00 00 00 10 00 10 07
06 00 08 04 00 00 00 00 c1 01 a4 57 00 00 00 00

Date/Time: 8/4/16 8:02:25 PM
Sequence number: 196317
Event type: 400C
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Alternate RAID controller module placed offline
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 0
Logged by: RAID Controller Module in slot 1

Raw data:
4d 45 4c 48 03 00 00 00 dd fe 02 00 00 00 00 00
0c 40 48 80 c1 01 a4 57 00 00 00 00 00 00 00 00
00 00 00 00 04 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 01 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 01 01 0c 00 00 00 08 00 10 07
06 40 08 04 00 00 00 00


Date/Time: 8/4/16 7:59:41 PM
Sequence number: 196316
Event type: 1400
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Password reset
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 0
Logged by: RAID Controller Module in slot 0

Raw data:
4d 45 4c 48 03 00 00 00 dc fe 02 00 00 00 00 00
00 14 48 10 1d 01 a4 57 00 00 00 00 00 00 00 00
00 00 00 00 04 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 01 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 00 00 00 00 00 00


Date/Time: 8/4/16 7:57:40 PM
Sequence number: 196315
Event type: 1400
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Password reset
Event specific codes: 0/0/0
Component type: RAID Controller Module
Component location: Enclosure 0, Slot 0
Logged by: RAID Controller Module in slot 0

Raw data:
4d 45 4c 48 03 00 00 00 db fe 02 00 00 00 00 00
00 14 48 10 a4 00 a4 57 00 00 00 00 00 00 00 00
00 00 00 00 04 00 00 00 22 00 00 00 22 00 00 00
08 00 00 00 00 00 00 00 01 00 00 00 01 00 00 00
0a 00 00 00 01 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
01 00 00 00 00 00 00 00 00 00 00 00

This last event, 1400 Password reset, repeats every 3 or 4 min. What that means? 

And why is failing on the MDI? A controller card needs to be replaced?

Any help will be appreciate it!